Contents Overview

Events

Record flaring, venting, blowdown and well events with their times, quantities and causes.

Operational records → Events holds flaring, venting, blowdown and well events. Times are in UTC; an event that spans two months is split between them pro rata. Filter the list by Asset, Event type, Classification and month.

Record an event

  1. Click New event.
  2. Choose the asset and the Source, the Event type (Flaring, Venting, Blowdown or Well event) and the Classification (Routine, Non-routine, Safety, Purge & pilot).
  3. Enter Start (UTC) and End (UTC) and the quantity: Volume (Sm³) for flaring and venting; for a blowdown, Isolated volume (m³), Start pressure (kPa a), End pressure (kPa a), Temperature (°C) and the Z-factors. A blank Z-factor is taken as 1.0 with warning W034.
  4. Enter the Cause. Causes feed the Top causes table of the Flaring & venting dashboard.
  5. Optionally choose a Composition label; by default the source’s composition is used.
  6. Click Save. “Saved. A recalculation was queued for the affected months” confirms it.

Use Evidence on the row to attach a file. See Evidence files.

Checks

  • E030: missing or inconsistent event data, for example an end before the start.
  • E032: the event type is not allowed for the selected source (for example venting on a flare source).
  • E041: unknown composition label for this asset.
  • Events in a locked month are refused. Request a restatement first.

Events can also be imported with the Events sheet of the Excel template.